edges_cal.reflection_coefficient.CalkitStandard.termination_impedance

CalkitStandard.termination_impedance(freq: Annotated[Quantity, PhysicalType(‘frequency’)]) Annotated[Quantity, Unit('Ohm')][source]

The impedance of the termination of the standard.

See Eq. 22-25 of M16 for open and short standards. The match standard uses the input measured resistance as the impedance.